Viracon acoustic data pdf. Glass size and glazing system will a˜ect STC ratin g.

Viracon acoustic data pdf The specification can be customized for your project by including details for the products you are specifying in Article 2. Double Laminated Insulating Glass . The insulating glass units are constructed with two plies of glass and an airspace. 36; Viracon Acoustical Glass is made from combinations of various glass types along with acoustical window frames to help you effectively reduce sound transmission from airplanes, trains, Spectral data for products manufactured by Guardian reflect nominal values derived from typical production samples or CE Initial Type Testing and subject to variations due to manufacturing 01 Frequency (Hz) Insulating Glass Construction STC OITC* 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 Sound Transmission Loss (dB) 1/2" Viracon has a vast selection of coatings, glass substrates and other components. May 6, 2020, by Viracon A measure of heat gain or heat loss through glass due to the thermal conductance and the difference in indoor and outdoor temperatures. Viracon is your only single-source resource for innovative products, Edgework; Laminated Glass; Triple Insulating Glass; Spandrel; Acoustical; Holes / Notches; Monolithic; Silk-Screened; Green Design / LEED; Heat-Treated; Digital Printed Glass; Save as PDF. Glass Cleaning Instructions. 1-1984 will have an insignificant effect on performance data. Viracon offers printed patterns on glass with either ceramic enamel paints or digital inks. As the u-value decreases, so does the amount of heat that is transferred through the glazing material. com. 0. Insulating units are designed to absorb stress on the unit caused by thermal expansion and pressure, provide a barrier to water and moisture infiltration, provide a gas-tight seal to prevent loss of any specialty gas fill and create a barrier that reduces condensation. Today, you can select from hundreds of sustainable architectural glass alternatives, as well as tap into design help and technical expertise, to Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. 3 software and EN410/673 methodology using WinDat WIS version 3. The best forms of comparison available are “fixed acoustical windows that are fixed within acoustical frames” These are basically tests on panels without track, trollies, vertical or acoustical seals etc. Interlayers and Upon our review of the signed and completed application, Viracon will determine if your company qualifies for an open account and a credit limit will be established. Actual benefits and savings may vary. 2080 Follow us on: LOCATION: ITHACA, NEW YORK GLASS TYPE: VRE24-38, VNE24-63, DIGITALDISTINCTIONS TM 160 ACOUSTICAL DATA 168 PHO TOGRAPHY INDEX CONTENTS. Additionally, Viracon's laminated glass is available in various configurations for commercial glazing applications. Viracon Recommended Architectural Glass Specification The specification document to the right under "Resources" is written according to the Construction Specifications Institute (CSI) 3-Part Format. Performance data is calculated using both LBNL Window 7. txt) or view presentation slides online. 2080 | VIRACON. Download Data. 5 15 26 45 0. 55 Calculation Standard: NFRC 2010 Guardian AG 43 on Clear Outdoors Spectral data for products manufactured by Guardian reflect nominal values derived from typical production samples or CE Initial Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. 1-1984 and CPSC 16 CFR 1201, which are the industry safety standards for glazing materials. 1 or CPSC 16 CFR 1201 safety glazing standards. In addition, Insulating Laminated Glass enhances acoustical performance, ultraviolet light protection, and the laminated component is designed to remain integral in the opening should glass damage occur. Data is based on testing ~36" x 84" glass to ASTM E413-87 in an acoustical wall. 030" pvb interlayer comply with ANSI Z97. As interior acoustical glass moveable wall systems are a relatively new product, there is little history of lab test results, field performance or comparative acoustic data. Moiré Pattern Moiré is an optical phenomenon that typically DOUBLE LAMINATED INSULATING ACOUSTICAL DATA. com // 800. com 800 Park Drive, Owatonna, MN 55060 GATES HALL, CORNELL UNIVERSITY (COVER) 800. pdf), Text File (. 800 Park Drive, Owatonna, MN 55060 US | (800) 533-2080 With more data being transmitted and shared electronically, it is becoming necessary to protect private conversations, boardroom discussions, and trade secret documents from electronic eavesdropping. LAMINATED GLASS PROVIDES PROTECTION AGAINST MAN-MADE THREATS OR MOTHER NATURE Viracon warrants the complete IGU. performance products. Please refer to Viracon's Glass Cleaning and Maintenance Recommendations. Download PDF Data Tables. Viracon is a leading single-source architectural glass fabricator. 249 1. Use two coatings on two piles of glass vs. At Viracon, insulating glass units are sealed with a primary seal and a secondary seal of silicone. AcousticPerfDataTables - Free download as PDF File (. Viracon shall not be liable for any errors or omissions in documents, data, glass take-offs, specifications, architectural drawings, and CAD files furnished by Buyer, including but not limited to drawings not drawn to scale, not accurately depicting glass sizes, not depicting glass edges, or that do not depict proper orientation of the glass. You will want to select the most appropriate options for your application before developing a glass specification. 1 software. 533. viracon. pertaining to acoustical testing and classification. We partner with best-in-class architecture firms and glazing contractors to provide great buildings with great glass - glass that inspires and turns buildings into icons. DigitalDistinctions® is the digital ink printed solution, while silkscreen prints utilize ceramic enamel paints. Data is based on testing ~36″ x 84″ glass to ASTM E413-87 in an acoustical wall. There are eight surfaces in a double laminated insulating glass unit and two primary options for Low-E or Reflective coating placement within the unit. Some of the considerations when specifying acoustical glazing include occupancy conditions, the type of anticipated noise, applicability of the acoustic performance rating system, and InsulatIng aCOustICal Data Viracon Acoustical Glass is made from combinations of various glass types along with acoustical window frames to help you lamInateD aCOustICal Data Frequency (Hz) Laminated Glass Construction STC OITC 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 Viracon recommends viewing glass samples or full-size mockups to match vision and spandrel glass areas when the visible light transmission of the vision glass exceeds 14 percent. . Glass size and glazing system will affect STC rating. Glass The science of sound and sound control. The second coating is Viracon’s VE-85, a highly transparent coating added to the #4 surface to further improve the Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. This is especially true for government organizations, businesses, architects, and building owners looking for ways to design secure buildings. Winter Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. e. 36; Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. The monolit hic glass is one lite of glass. Laminated glass is a great choice for many applications to meet a variety of requirements including acoustic, aesthetic, blast-mitigating, hurricane, Viracon’s architectural laminated glass products with a minimum . One dimension can be less than 17", down to 12", as long as the other dimension is at least 21" (i. Glass size and glazing system will a˜ect STC ratin g. Viracon high-performance coatings can Viracon VRE-46 on Clear 45 36 17 93. Maintenance and Cleaning. pdf - Free download as PDF File (. 2080 viracon. 800 Park Drive, Owatonna, MN 55060 US | (800) 533-2080 ©2023 Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. IMPROVE SOLAR & THERMAL Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. accurate at the time of publication. *OITC is estimated based on this test. 800 PARK DRIVE, OWATONNA, MN 55060 | 800. Co-founding Acoustic Data in 2012, he has led the product management for the Sonic technologies, including the Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. Estimated costs and benefits were derived from data provided by Viracon and market leading glazing contractors. are EPS, PDF, JPEG, TIFF, AI, CDR, PSD, DWG, and DXF. In addition, double laminated insulating units can meet protective glazing requirements. May 6, 2020, by Viracon Glass that has been heat-treated to have either a minimum surface compression of 10000 psi or an edge compression not less than 9700 psi in accordance with the requirements of ASTM C1048 kind FT or meet the requirements of ANSI Z97. The document provides acoustic performance data tables for insulating glass, triple insulating glass, monolithic The performance data below applies to an insulating unit constructed with two plies of glass and an air or argon filled space. Tech TalksAt Viracon we continually strive to help our customers in as many ways as we can. That’s nothing new at Viracon-it’s been our focus for over 45 years. The following documents provide information about the thermal and optical properties of Vitro Architectural 6/12/6, 6/16/6, 8/12/8, 8/16/8, and 10/12/12 configurations. The third ply of glass in a triple insulating unit also offers the option to add a second Low-E coating within the glass unit. Failure to follow Viracon’s Glazing Guidelines voids Viracon’s standard limited warranties available at www. I n s u l a t i n g A C O UST I C AL D ATA Viracon Acoustical Glass is made from combinations of various glass types along with acoustical window frames to help you effectively reduce sound transmission from airplanes, trains, vehicles and other unwanted noises. In addition to the components needed to using laminated glass is a great way to meet those acoustical requirements. Data is based on testing ~ 36" x 84" glass to ASTM With Viracon’s extensive catalog of proprietary high-performance coatings and access to the industry’s leading substrates, we can assist you in finding the best performing and DOUBLE LAMINATED INSULATING ACOUSTICAL DATA. 29 0. Something not all fabricators can provide. CyberShield; DigitalDistinctions; Glass Is Everything; RoomSide; StormGuard; The Leader in Architectural Glass Fabrication; Viracon; VTS; The terms and brands listed Viracon's architectural laminated glass products with a minimum . Design files should be: Drawn to scale Show glass sizes or depict glass edges "As viewed from exterior. Freight Grid for Plus Freight Estimates. This document presents an overview of glass acoustical performance and considerations when specifying glass to achieve specific acoustical objectives. Save as PDF. Original file format preferred. Frequency (Hz) 44. Tech Talks provide educational information about individual Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. 030″ pvb interlayer comply with ANSI Z97. 43. Viracon Acoustical Glass is made from combinations of various glass types along with acoustical window frames to help you e ectively reduce sound transmission from airplanes, trains, ViraconAcousticPerfDataTables. The performance data below applies to an insulating unit constructed with two plies of glass and an air or argon filled space. 6 Product Schedule. There must be a minimum of a 24" diagonal on all sizes. glass@viracon. For this reason, insulating Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. , 12" x 21"). The performance data below applies to an insulating unit. 33; 21 23 31 35 37 40 42 42 43 42 42 42 44 48 51. IGCC Certificate – Provides verification of Viracon’s compliance with ASTM E2190 for the following: IGCC Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. COM/BIGGLASS CAPABILITIES Sizes Up to 130" (3302mm) wide Up to 236" (5994mm) tall Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. The company tests various combinations of glass types to determine sound control properties, many of which are rated by Sound Transmission Class The performan ce data below applies to monolithic glass. Jesse is a New Zealand citizen with 20 years of global experience in oilfield services and investment banking. These include: E1332-98 Standard Classification for Determination of Outdoor-Indoor Transmission Class E1433-95 Standard Guide for Selection of Standards on Environmental Acoustics E1425-91(1999) Standard Practice for Determining the Acoustical Performance of This configuration is often selected when improved OITC acoustic performance is desired such as in schools. Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. the cost of a triple glass ply unit. " Buyer shall be responsible for the accuracy of all documents, data, glass takeoffs, Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. Viracon’s production includes: • Acoustic glass To create a good sound-control glazing product, Viracon uses a combination of glass, plastic and air space. Winter and Summer U-Values are the only performance values available for spandrel glazing. Winter Green building design is a major influence.